Cross Flow Membrane Module for Liquid Separation/ PVDF / Pes Membrane Material / Alkali Resistance UF Membrane for Acid and Alkali Recycle

Product Details
Customization: Available
Membrane Type: Tubular
Type: UF
Manufacturer/Factory & Trading Company
Diamond Member Since 2019

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
90
Management System Certification
ISO9001:2015
  • Cross Flow Membrane Module for Liquid Separation/ PVDF / Pes Membrane Material / Alkali Resistance UF Membrane for Acid and Alkali Recycle
  • Cross Flow Membrane Module for Liquid Separation/ PVDF / Pes Membrane Material / Alkali Resistance UF Membrane for Acid and Alkali Recycle
  • Cross Flow Membrane Module for Liquid Separation/ PVDF / Pes Membrane Material / Alkali Resistance UF Membrane for Acid and Alkali Recycle
  • Cross Flow Membrane Module for Liquid Separation/ PVDF / Pes Membrane Material / Alkali Resistance UF Membrane for Acid and Alkali Recycle
  • Cross Flow Membrane Module for Liquid Separation/ PVDF / Pes Membrane Material / Alkali Resistance UF Membrane for Acid and Alkali Recycle
  • Cross Flow Membrane Module for Liquid Separation/ PVDF / Pes Membrane Material / Alkali Resistance UF Membrane for Acid and Alkali Recycle
Find Similar Products

Basic Info.

Module Od
8inch
Tube ID
8mm
Module Length
3000mm
Shell Material
FRP
Mwco
30nm
Replacement
Pentair
Transport Package
Wooden Box
Specification
8830
Trademark
RisingSun
Origin
China
HS Code
84219990
Production Capacity
300piece/Month

Product Description

Risingsun Tubular UF Membranes, 30nm, PVDF membrane for waste water treatment, Cross Replacement Pentair X-FLOW Compact 27/ UF membranes

Wastewater treatment landfill leachate


Leachate from landfills and incinerators arises mainly because rainwater penetrates the stored waste, but also from leakage of the garbage. The polluted leachate is collected by the garbage dump and undergoes special wastewater treatment.
The wastewater from landfills is characterized by a high variety of waste.

Tubular membranes are particularly suited to liquid with high viscosity or suspended solids, because their wide flow paths make them highly resistant to clogging. Tubular membranes system is an external and separated filtration system. For high solid content and viscosity liquid, we use adjustable cross-flow velocity to make the membrane run under optimal conditions and extend membrane service life. At the same time, it has more convenient cleaning, maintenance, and operation under closed pipeline.

Cross Flow Membrane Module for Liquid Separation/ PVDF / Pes Membrane Material / Alkali Resistance UF Membrane for Acid and Alkali Recycle

SUN® Tubular membranes use a cross-flow filtration technology. The cross-flow filtration can reduce cleaning times and downtime, so as to maintain a high flow rate. Some membranes are available for back washing, if necessary, you can also use permeate or chemical cleaner for back washing, effectively extend the membranes working life.

Cross Flow Membrane Module for Liquid Separation/ PVDF / Pes Membrane Material / Alkali Resistance UF Membrane for Acid and Alkali Recycle

Decoding of SUN® Tubular Membranes Model

Cross Flow Membrane Module for Liquid Separation/ PVDF / Pes Membrane Material / Alkali Resistance UF Membrane for Acid and Alkali Recycle
 What Membrane Sheet We Have? 

  Hydrophilic membrane sheet specifications:
Parameter Unit  Membrane Material                      
 PVDF PAN PES
Pore size/MWCO nm/Dalton 100,000 30nm 50,000 0.1μm 100,000 50,000 10,000 5,000
Clean Water Flux LMH,
100kpa
>800 >800 >150 >600 >350 >200 >25 >15
Operation Pressure Kpa -20~800 -20~800
Max.Operation Temperature ºC 60 60
pH Range   2~12 2~12
Chloringe Exposure ppm.h 250,000 250,000
Note: Membrane inner tube diameter is 5-12.7mm; Superior fouling resistance; Higher sustainable flux; Easier cleaning;
Strong negative pressure resistance.
Maximum operating pressure up to 10bar, Working life up to more than 5 years.


SUN® Tubular Membranes / an external MBR for Landfill Leachate 

The external tubular membrane system is a kind of process mainly for high concentration wastewater treatment,
especially for landfill leachate. It is composed of biochemical process and external tubular UF membrane system.
Pollutants such as organic matter will be removed through biochemical process and the sludge and water will be
separated through the external tubular UF membranes, so as to get high quality ultrafiltration water, and the
concentrated water will return to the biochemical tank. The designed flux is up to 70~120LMH, and the filtration
accuracy can reach 0.03um. The 8mm diameter channel can effectively retain the sludge without causing membrane
fouling. The maximum sludge concentration can up to 40mg/l.


RisingSun Tubular UF membranes, 30nm, PVDF for landfill leachate, cross replacement Berghof membranes.
Use of RisingSun Membranes tubular UF filtration ensures complete solids retention, efficient system operation and process stability at all times.
External crossflow filtration technology is a good choice for :
Superior Effluent Quality
Increased Treatment Capacity
Smaller Footprint
Low Sludge Production


Cross Flow Membrane Module for Liquid Separation/ PVDF / Pes Membrane Material / Alkali Resistance UF Membrane for Acid and Alkali Recycle
The combination of the tubular UF membrane system with RO or NF can make the landfill leachate effluent 
meet China government level 1 & level 2 discharge standards.

 
Specifications:
Model
Tube ID. 
(mm)
Module OD.
(inch)
Module Length
(mm)
Membrane Area
(m2)
Clean Water Flux
@100kpa(T/H)
TG-30nm-8410
8.0
4.0
1000
2.1
1.68
TG-30nm-8430
8.0
4.0
3000
6.4
5.12
TG-30nm-8630
8.0
6.0
3000
15.2
12.16
TG-30nm-8830
8.0
8.0
3000
27.2
21.16
TG-30nm-81040
8.0
10.0
4000
53.4
42.72
We can offer customized membrane module, especially for small size pilot modules.
 

 
Membrane Module: TG-30nm-8830, Operation Parameters (an example)
Working principle cross filtration Flux per module 1.9t/h
Operation pressure 5 bar/5 modules Chemical cleaning frequency 1-2 month
Flux rate 70 LMH Pressure drop. 0.8 bar
 
Reference of selection tubular membranes in the field of landfill leachate
Daily Capacity Q (m³/d) Q≤50 50Q≤120 120Q≤250 250≤Q≤400 300Q≤450
Module size 4inch diameter,
3 meter length
6inch diameter,
3 meter length
8inch diameter,
3 or 4 meter length
10inch diameter,
3 meter length
10inch diameter,
4 meter length
Module qty. 3-6 pcs 3-6 pcs 4-6 pcs 4-6 pcs 4-6 pcs


SUN® On Site Application Pictures

Cross Flow Membrane Module for Liquid Separation/ PVDF / Pes Membrane Material / Alkali Resistance UF Membrane for Acid and Alkali Recycle
Cross Flow Membrane Module for Liquid Separation/ PVDF / Pes Membrane Material / Alkali Resistance UF Membrane for Acid and Alkali Recycle
Cross Flow Membrane Module for Liquid Separation/ PVDF / Pes Membrane Material / Alkali Resistance UF Membrane for Acid and Alkali Recycle
Applications:
Difficult waste water fields:
Landfill leachate pretreatment
Pretreatment for alkali liquor recycle
Special chemical waste water (Coking, Tannery, textile, wood pulp bleach) treatment
Return injection of produced water from oil field
Emulsified oil treatment


Cross Replacement: Berghof membranes/ Pentair Membranes


Membrane Storage:
New membrane modules can be stored as supplied.
Membrane modules should be stored in a dry, normally ventilated place, away from sources of heat, ignition and direct sunlight.
Store between 0 and 40 °C. The membrane modules should not be subjected to any freezing temperatures.
After use, UF membranes need to be stored wet at all times.
To avoid biological growth during shutdowns or storage, wet membranes should be treated with a compatible biocide.
The membrane is compatible with many common disinfecting agents or biocidal preservatives. For short-term shutdowns, a daily flush with permeate quality water containing up to 2.0 ppm free available chlorine for 30 to 60 minutes may be adequate for bacteria control.
In case of long-term storage, membranes should be cleaned before the disinfection step is carried out.
For disinfection, a 1% sodium metabisulfite solution can be used.
In either situation, modules should be stored hydraulically filled.


FAQ
 1, Q: Are you manufacturer?
     A:Yes, definitely,our factory locate in Beijing,China.
 
 2, Q:What's your main products ?
     A: we manufactur filter membranes, RO, NF, UF, MF membrane, spiral wound/flat sheet membrane, tubular membrane, MBR, DTRO,
STRO,E-coat UF membrane, anode cell etc.
 
 3, Q: what's your main market?
     A:There're about 94 countries we've been exported, mainly in USA, Korea, UK, France, Russia, Germany, India, Spain, Brazil etc.
 
4, Q:Can you supply free sample?
    A:Yes, we can supply free samples which are in stock, and the freight charge should be on your side.
 
5, Q: What about the package?
    A:The membrane elements are wrapped with plastic bubble paper, then carton box, safe wooden box outise, the breakage is less than 1%.
 
6, Q: Do you offer OEM?
    A: Sure!


Cross Flow Membrane Module for Liquid Separation/ PVDF / Pes Membrane Material / Alkali Resistance UF Membrane for Acid and Alkali Recycle
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier