Parameter | Unit | Membrane Material | |||||||
PVDF | PAN | PES | |||||||
Pore size/MWCO | nm/Dalton | 100,000 | 30nm | 50,000 | 0.1μm | 100,000 | 50,000 | 10,000 | 5,000 |
Clean Water Flux | LMH, 100kpa |
>800 | >800 | >150 | >600 | >350 | >200 | >25 | >15 |
Operation Pressure | Kpa | -20~800 | -20~800 | ||||||
Max.Operation Temperature | ºC | 60 | 60 | ||||||
pH Range | 2~12 | 2~12 | |||||||
Chloringe Exposure | ppm.h | 250,000 | 250,000 | ||||||
Specifications:
|
||||||||
Model
|
Tube ID.
(mm)
|
Module OD. (inch) |
Module Length (mm) |
Membrane Area (m2) |
Clean Water Flux @100kpa(T/H) |
|||
TG-30nm-8410
|
8.0
|
4.0
|
1000
|
2.1
|
1.68
|
|||
TG-30nm-8430
|
8.0
|
4.0
|
3000
|
6.4
|
5.12
|
|||
TG-30nm-8630
|
8.0
|
6.0
|
3000
|
15.2
|
12.16
|
|||
TG-30nm-8830
|
8.0
|
8.0
|
3000
|
27.2
|
21.16
|
|||
TG-30nm-81040
|
8.0
|
10.0
|
4000
|
53.4
|
42.72
|
|||
We can offer customized membrane module, especially for small size pilot modules.
|
Membrane Module: TG-30nm-8830, Operation Parameters (an example) | |||
Working principle | cross filtration | Flux per module | 1.9t/h |
Operation pressure | 5 bar/5 modules | Chemical cleaning frequency | 1-2 month |
Flux rate | 70 LMH | Pressure drop. | 0.8 bar |
Reference of selection tubular membranes in the field of landfill leachate | |||||
Daily Capacity Q (m³/d) | Q≤50 | 50≤Q≤120 | 120≤Q≤250 | 250≤Q≤400 | 300≤Q≤450 |
Module size | 4inch diameter, 3 meter length |
6inch diameter, 3 meter length |
8inch diameter, 3 or 4 meter length |
10inch diameter, 3 meter length |
10inch diameter, 4 meter length |