• pH Stable Spiral NF Membrane for Acid and Caustic Recovery, Cross Refer: Mps-34 Koch
  • pH Stable Spiral NF Membrane for Acid and Caustic Recovery, Cross Refer: Mps-34 Koch
  • pH Stable Spiral NF Membrane for Acid and Caustic Recovery, Cross Refer: Mps-34 Koch
  • pH Stable Spiral NF Membrane for Acid and Caustic Recovery, Cross Refer: Mps-34 Koch
  • pH Stable Spiral NF Membrane for Acid and Caustic Recovery, Cross Refer: Mps-34 Koch
  • pH Stable Spiral NF Membrane for Acid and Caustic Recovery, Cross Refer: Mps-34 Koch

pH Stable Spiral NF Membrane for Acid and Caustic Recovery, Cross Refer: Mps-34 Koch

Membrane Type: Spiral
Type: NF
Membrane Material: Composite
Mwco: 200-400 Dalton
Operation Pressure: 15-35 Bar
Length: 40inch
Samples:
US$ 2500/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2019

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
NF-8040
Acid
15% H2so4
Caustic
20% Naoh
Acid Resistance
5% HCl
Transport Package
Pallet
Specification
4040/8040
Trademark
RisingSun
Origin
China
HS Code
84219990
Production Capacity
500piece / Month

Product Description

Membrane Characteristics:
We use Composite nanofiltration membrane in a spiral wound configuration, with superior pH and temperature stability.

Operating Limits:
• Maximum operating pressure for NF6-8040 is 510 psi (35 bar).
Actual operating pressure is dependent upon system flux rate, as well as feed,
recovery and temperature conditions.
• Permeate Pressure: Maximum allowed permeate pressure is 3 psi (0.2 bar).
• Differential Pressure: Maximum differential pressure limit is 10 psi (0.7 bar) per element.
Maximum differential pressure for any length vessel is 50 psi (3.5 bar).
• Temperature: Maximum operating temperature is 65°C.
• pH: Allowable range for continuous operation is 0-14.

When a stainless steel permeate tube is used, corrosive acids should be avoided.

Cross replacement refer: 
SelRO® MPS-34 - pH Stable Membrane


Feed channel spacers: 31 mil and 46 mil 

Feed Flow Rate: Maximum and minimum flow rate are as follows:
2540 Minimum 2 gpm (7.5 liter/min) ; Maximum 5 gpm (19 liter/min)
4040 Minimum 6 gpm (22 liter/min) ; Maximum 17 gpm (65 liter/min)
8040 Minimum 25 gpm (95 liter/min); Maximum 75 gpm (285 liter/min)
Actual feed flow rate is dependent upon system flux rate, feed characteristics, fouling tendency and system design:


Lubricants: For element installation, use only water or glycerin to lubricate seals.
The use of petroleum or vegetable-based oils or solvents may damage the element and will void any warranty.


Dimensions:
pH Stable Spiral NF Membrane for Acid and Caustic Recovery, Cross Refer: Mps-34 Koch
Why us:
1. We use high quality membrane sheet and automatic rolling machine to promise high & steady membrane performance.
2. We have rich membrane application experience.
3. Our NF membrane element is cross replacement for brand Koch, Synder, Microdyn Nadir, Nanostone, DOW etc.
4.We offer OEM service.
5. Competitive price and fast delivery.
6. Free testing sample is available.

pH Stable Spiral NF Membrane for Acid and Caustic Recovery, Cross Refer: Mps-34 Koch


pH Stable Spiral NF Membrane for Acid and Caustic Recovery, Cross Refer: Mps-34 Koch
Our Team:

pH Stable Spiral NF Membrane for Acid and Caustic Recovery, Cross Refer: Mps-34 Koch


 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2019

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
Number of Employees
90
Management System Certification
ISO9001:2015