Customization: | Available |
---|---|
Membrane Type: | Tubular |
Type: | UF |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Model | A | B | C | D | E | F | ||
(mm) | (mm) | (mm) | (mm) | (mm) | (mm) | |||
TG-UF100-5830 | 3000 | 219.1 | 210 | 90 | 73 | 165 |
Typical Operation Pressure: Max.Operation Pressure: Min.Outlet Pressure: Max.Operation Temperature (pH:8): Max. Temperature for CIP: pH-Continuous Operation @25ºC: pH-CIP @40ºC: Max. Chlorine Exposure For special industry applications, please contact us. |
28-72.5 psi (2.0-5.0 bar) 116 psi (8.0 bar) 10 psi (0.7 bar) 140°F (60ºC) 104°F (40ºC) 2.0-11.0 2.0-12.0 250,000ppm·h |
Parameter | Unit | Membrane Material | |||||||
PVDF | PAN | PES | |||||||
Pore size/MWCO | nm/Dalton | 100,000 | 30nm | 50,000 | 0.1μm | 100,000 | 50,000 | 10,000 | 5,000 |
Clean Water Flux | LMH, 100kpa |
>800 | >800 | >150 | >600 | >350 | >200 | >25 | >15 |
Operation Pressure | Kpa | -20~800 | -20~800 | ||||||
Max.Operation Temperature | ºC | 60 | 60 | ||||||
pH Range | 2~12 | 2~12 | |||||||
Chloringe Exposure | ppm.h | 250,000 | 250,000 | ||||||
Applications:
Wastewater treatment, tubular membranes can be used to treat industrial wastewater and sewage, removing hazardous substances from them in order to comply with environmental regulations and recover water resources.